Volume (m3) of concrete required per piece. (Check with your engineer for the grade of concrete required for your project.)
Core Size 100 mm: = 0.048 m3
Core Size 150 mm: = 0.067 m3
Core Size 200 mm: = 0.093 m3
Core Size 250 mm: = 0.122 m3
To assemble a SINGLE One Series Form Unit you will require the following components:
FOR A 90 Degree Corner Outside;
1 x EPS Panel (Priced here)
1 x Plywood Panel (Plwood panels to be cutt on site. Sepeartely priced)
8 x Screws (Sepeartely priced)
4 x Multi form Ties (Sepeartely priced)
4 x Insert webs (Sepeartely priced)
1 x Jig (Reusable) (Sepeartely priced)
Reinforcement required
NUDURA have developed reinforcement tables based on European and North American code you can refer to these as guidance but always comply with your local code.